Resolution of up to 8192 angle steps per sine/cosine period
Binary and decimal resolution settings, e.g. 500, 512, 1000, 1024; programmable angle hysteresis
Conversion time of just 250 ns including amplifier settling
Count-safe vector follower principle, realtime system with 70MHz sampling rate
Direct sensor connection; selectable input gain
Front-end signal conditioning features offset (8 bit), amplitude ratio (5 bit) and phase (6 bit) calibration
Parameterization and absolute angle output via bidirectional high-speed synchronous-serial BiSS Interface (B protocol)
A QUAD B incremental outputs with selectable minimum transition distance (e.g. 0.25 μs for 1MHz at A)
Index signal processing adjustable in position and width
Fault monitoring: frequency, amplitude, configuration (CRC)
Multiturn counting to 8 bit or 24 bit
Fully re-programmable by BiSS interface with access to serial EEPROM to store setup
ESD protection and TTL-/CMOS-compatible outputs